Revealing the Real Story Behind Motor Power and VFD Ratings: Avoid Costly Mistakes

October 24, 2024

Understanding Motor Power Rating and VFD Ratings: The Reality Behind Normal Duty and Heavy Duty Selections

When it comes to selecting a VFD for a motor, many professionals start with the values provided for Normal Duty (ND) and Heavy Duty (HD). It seems straightforward — these ratings supposedly help match a drive to a motor based on its operating cycle. But here’s the truth: these numbers can be misleading. In fact, the Heavy Duty rating is essentially a derated version of the VFD’s Normal Duty value.

Breaking Down Normal Duty and Heavy Duty Ratings

Variable Frequency Drives usually come with two sets of ratings: one for ND and one for HD.

  • Normal Duty (ND) covers applications with lower torque needs and fewer overload requirements.
  • Heavy Duty (HD) applies when you need higher starting torque, frequent speed changes, or higher overload capacity.

Now, here’s the trick: these ratings aren’t as independent as they may seem. The Heavy Duty number is simply a reduced version of the Normal Duty rating. So, a VFD rated for 30 kW in Normal Duty could only handle 22 kW in Heavy Duty. What’s important to understand is that these two numbers don’t represent different capabilities — HD is just the drive operating in a more restrictive condition.

Why Current Is More Important Than Motor Power Rating

In real-world conditions, the current the motor draws is what really matters, not the power rating printed on the VFD’s datasheet.

  • Current Rules the Day:
    Motors running at full load, especially when they need high torque, will draw more current. If you select a VFD based on power alone, without considering current, you risk choosing a drive that’s undersized for the job.
  • Operating Cycles Matter:
    Motors with fluctuating loads, like pumps or conveyors, will have varying current demands. You need to account for both the motor’s full load current and its peak conditions to avoid miscalculations.
The Service Factor: How It Impacts Variable Frequency Drive Selection in North America

In North America, many motors come with a service factor — this lets the motor temporarily operate above its rated capacity. For example, a motor with a 1.15 service factor can handle 115% of its rated load for short periods. This can be helpful for overloads, but there are a few things to keep in mind:

  • Overuse Equals Overheating:
    Relying too much on the service factor can lead to overheating, which reduces the motor’s life.
  • Don’t Forget the VFD:
    If the motor is operating beyond its rated capacity due to its service factor, the VFD has to manage the extra current load. Make sure the drive can handle that — otherwise, you’re risking faults and unnecessary trips.
IEC 60034-1: Defining Motor Services Beyond North America

If you’re dealing with motors in regions that follow IEC standards, the IEC 60034-1 standard comes into play. It classifies motor services into different duty cycles, and this affects both motor and VFD selection:

  • S1 (Continuous Duty): The motor runs continuously under a constant load. The Variable Frequency Drive needs to handle continuous operation at rated current.
  • S2 (Short-Time Duty): The motor runs at full load for a limited time, followed by a cool-down period. The VFD needs to handle fast accelerations and decelerations.
  • S3 (Intermittent Periodic Duty): The motor runs in cycles of load and rest. Peak current handling becomes critical for the VFD.
  • S6 (Continuous Duty with Periodic Load Variations): The motor operates continuously, but the load varies. The VFD must manage fluctuating current and torque demands.

Understanding these IEC classifications helps ensure you’re not just looking at peak load conditions but also how the motor and Variable Frequency Drive operate under real-world cycles. Selecting the right VFD means matching it to the motor’s actual service duty, not just theoretical peak ratings.

The Bottom Line: Focus on Current, Not Just Power Ratings

At the end of the day, ND and HD ratings might help with an initial selection, but they’re far from the whole picture. You need to consider the motor’s actual current demands during operation. Combine that with a solid understanding of the service factor (if applicable) and IEC duty classifications, and you’ll be much closer to choosing the right VFD for the job. The goal is to avoid underestimating the current load, which could result in costly downtime or performance issues down the road.

Follow the step-by-step approach described in the Clean Power VFD user guide to select the VFD that fits your application: /clean-power-vfd-publication/vfd-selection

Source

Related Articles


Changing Scene


Sponsored Content
The Easy Way to the Industrial IoT

The way to the Industrial IoT does not have to be complicated. Whether access to valuable data is required or new, data-driven services are to be generated, Weidmuller enables its customers to go from data to value the easy way. Weidmuller’s comprehensive and cutting-edge IIoT portfolio applies to greenfield and brownfield applications. Weidmuller offers components and solutions from data acquisition, data pre-processing, data communication and data analysis.

Visit Weidmuller’s Industrial IoT Portfolio.


ADVANCED Motion Controls Takes Servo Drives to New Heights (and Depths) with FlexPro Extended Environment Product Line

Advanced Motion Controls is proud to announce the addition of six new CANopen servo drives with Extended Environment capabilities to their FlexPro line. These new drives join AMC’s existing EtherCAT Extended Environment FlexPro drives, making the FlexPro line the go-to solution for motion control applications in harsh environments.

Many motion control applications take place in conditions that are less than ideal, such as extreme temperatures, high and low pressures, shocks and vibrations, and contamination. Electronics, including servo drives, can malfunction or sustain permanent damage in these conditions.

Read More


Service Wire Co. Announces New Titles for Key Executives

Bruce Kesler and Mark Gatewood have been given new titles and responsibilities for Service Wire Co.

Bruce Kesler has assumed the role of Senior Director – Business Development. Bruce will be responsible for Service Wire’s largest strategic accounts and our growing Strategic Accounts Team.

Mark Gatewood has been promoted to the role of Vice President – Sales & Marketing. In this role, Gatewood will lead the efforts of Service Wire Company’s entire sales and marketing organization in all market verticals.

Read More


Tri-Mach Announces the Purchase of an Additional 45,000 sq ft. Facility

Tri-Mach Elmira Facility

Recently, Tri-Mach Inc. was thrilled to announce the addition of a new 45,000 sq ft. facility. Located at 285 Union St., Elmira, ON, this facility expands Tri-Mach’s capabilities, allowing them to better serve the growing needs of their customers.

Positioning for growth, this additional facility will allow Tri-Mach to continue taking on large-scale projects, enhance product performance testing, and provide equipment storage for their customers. The building will also be the new home to their Skilled Trades Centre of Excellence.

Read More


JMP Parent Company, CONVERGIX Acquires AGR Automation, Expanding Global Reach

Convergix Automation Solutions has completed the acquisition of AGR Automation (“AGR”), a UK-based provider of custom, high-performance automation design and systems integration primarily to the life sciences industry.

Following Convergix’s acquisitions of JMP Solutions in August 2021 and Classic Design in February 2022, AGR marks the third investment in Crestview’s strategy to build Convergix into a diversified automation solutions provider targeting the global $500+ billion market, with a particular focus on the $70 billion global systems integration and connectivity segments. Financial terms of the transaction were not disclosed.

Read More


Latest Articles

  • Implementing Functional Safety Requirements

    Implementing Functional Safety Requirements

    The Safety Functional Requirements Specification (SFRS; sometimes referred to as SRS or Safety Requirements Specification) is the plan for the safety controls on a machine and is the second step of the safety lifecycle. The SFRS document serves as a framework for the safety control system design, is informed by prior work done in the… Read More…

  • From Endress+Hauser, 24/7 Digital, Plant-Wide Health Monitoring for Rockwell Systems Optimizes Workflows and Processes

    From Endress+Hauser, 24/7 Digital, Plant-Wide Health Monitoring for Rockwell Systems Optimizes Workflows and Processes

    Endress+Hauser’s Asset Health Monitoring Solution–Rockwell Edition, now available for installation, provides operators with a centralized, digital overview of plant-wide device health to avoid unscheduled shutdowns and accelerate troubleshooting. It not only presents early visibility of problematic devices but distinguishes itself by adding likely causes and remedies to such a report so problems can be fixed… Read More…